EasyManua.ls Logo

Kenmore 795.71022.010 - 8-6 Freezer Fan Error (Er FF)

Kenmore 795.71022.010
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 30 -
8-6 Freezer Fan Error (Er FF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the air
flow.
While an error code is displayed,
the fan is not working.
3 Check the Fan motor.
Rotate fan using your hand.
It feel stuck or locked up, change the motor.
(Cause of ice or rust inside of motor)
4 Check the Fan motor voltage.
Result & SVC Action
Below 12 V
0 or 5 V
(1) ~ (2)
(2) ~ (3)
Change the PCB
Change the motor
Point Result SVC Action
<CON4>
Status
No airflow
Airflow
SVC Action
Go to 3
Go to 4
(1)
(2)
(3)