Kenmore 795.71043.01 - Damper Checking and Troubleshooting; Fan Motor Troubleshooting

Kenmore 795.71043.01
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 28 -
No
5
Checking flow
Damper checking method.
Inputting TEST Mode,
Check the damper and PCB.
6 Check the Fan motor.
Rotate fan using your hand.
It feel sticky, change the motor.
(Cause of ice or rust inside of motor)
Result & SVC Action
7 Check the F Fan motor voltage.
(1)(3)
(2)
(4)
Open
Closed
Not
working
1 Mode
2 Mode
1,2
mode
Damper is normal.
(Explain to customer)
Change the damper
Test
Mode
Damper
State
SVC Action
(1) to (2)
(3) to (4)
270 ~ 330
Ω
Other
270 ~ 330
Ω
Other
It’s normal
Change damper
It’s normal
Change damper
Test Point
Result SVC Action
Below 12 V
0 or 5 V
(1) ~ (2)
(2) ~ (3)
Change the PCB
Change the motor
Point Result SVC Action
StickyMotor Change the motor
Point Result SVC Action
<CON4>
(1)(2) (3)