- 29 -
8-7 Icing Fan Error (Er IF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the refrigerator door and Check the
air flow.
※
While an error code is displayed,
the fan is not working.
3 Check the Connector.
(Frozen caused the PCB short)
Result & SVC Action
Status
No windy
Windy
SVC Action
Go to the 3,4
Go to the 5
4 Check the Fan motor.
(Frozen, Lock, ect.)
5 Check the Fan motor voltage.
Below 7 V
0 or 5 V
(2) ~ (3)
(1) ~ (3)
Change the PCB
Change the motor
Point Result SVC Action
<CON7>
(1)Pin1, (2)Pin3, (3)Pin5