Troubleshooting ,-,,
I ilia I iiiiiiiiiiiii1[11 i IIIIIIII
Trouble Probable Cause Remedy
Unit Will not run. - Humidity level is too higtl • Raise humidistat setting
° No power ° Check 120 volt power source
_Unit will not shut
° Float is not free ° Free float from obstruction
off.
°
° Water is present in the
system
Unit will not dry out
completely
B0tfles continue to
empty.
Unit is not emptying.
° High humidity or low tem-
perature resulting in slow
evaporation
° Air is entering water reser-
voirs.
°
°
Dirty filter
Reservoir cap plunger
missing post in bottom of
cabinet.
Unit runs and shuts °
off before bottles
are empty °
Water runs out of
rear of unit.
Humidity levelis toohigh
Unit is not setup on a level
surface (Float will not sense
water at the rear of the cabi-
net.
° Air is entering water bottles
This is normai._,small
amount of water remains in
the cabinet.
Allow unit to continue opera-
tion.
° check: Caps to ensure tightness.
° Check for leak in water bottles.
° Are gaskets for caps in place
(see repair parts list).
"-Change to a fresh new filter.
° Check orientation of bottle.
Reposition so that reservoir
cap plunger is depressed by
post in bottom of cabinet.
o Raise humidistat setting (if
possible)
° Position unit level (Some car-
pet padding may allow unit to
set lower in the front than the
rear with the additional weight
of water bottles in the front of
the cabinet. Install coasters
under front casters.
° Make sure fill cap (with gas-
kets) and reservoir cap (with
O-ring) are tightened properly
CAUTION: Use only 32-14900 EPA Registered Bac{eriostat available from Sears
Retail store.
Use of other water treatment products may damage the filter elements.
Under no circumstances should you use water treatment products designed for
Roto belt or Ultrasonic humidifiers.