4.20 Receiver Section
Item Condition Measurement Adjustment Specifi-
cations
/Remarks
Panel tuning mode PC test mode Test-
equip-
ment
Unit Ter-
minal
Unit Parts Method
1.
AF level
setting
[Panel test mode]
1) CH-Sig: 1-1
SSG output:
-47dBm (1mV)
(MOD: 1kHz/
±1.5kHz)
1) Test Channel
Channel: 1
Test Signaling
Mode: Analog
Signaling: 1
SSG output:
-47dBm (1mV)
(MOD:1kHz/
±1.5kHz)
SSG
DVM
AF VM
Dummy
load
Panel ANT
Uni-
versal
con-
nector
Panel Vol-
ume
knob
Turn the Volume knob to
obtain 0.90V AF output.
0.90V
±0.1V
2. Sensi-
tivity 2
1) Adj item:
[An SENS2]
Adjust:[***]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[***]
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Sensitivity 2]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Apply All]
button to store the
adjustment value.
SSG
AF VM
Dummy
load
Panel ANT
Uni-
versal
con-
nector
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[],
[]
Write the value as follow-
ings.
[Low1]: 45 (Fixed)
[Low3]: 100 (Fixed)
[Center2]: 150 (Fixed)
[High1]: 190 (Fixed)
[High3]: 240 (Fixed)
3. Sensi-
tivity 1
1) Adj item:
[An SENS2]
Adjust:[***]
2) Adj item:
[Low1]
[Low5]
[Center3]
[High2]
[High6]
SSG output:
-118dBm
(0.28μv)
(MOD:
1kHz/±1.5kHz)
Adjust:[***]
1) Adj item:
[Sensitivity 2]
2) Adj item: [Low1],
[Low5], [Center3],
[High2], [High6]
SSG output:
-118dBm
(0.28μv)
(MOD:
1kHz/±1.5kHz)
Press [Apply All]
button to store the
adjustment value.
SSG
Distor-
tion
meter
Oscil-
lo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel Write the value as follow-
ings.
Increase the adjustment
value from 1 get 12dB SI-
NAD.
4. RSSI
refer-
ence
1) Adj item:
[An RRSSI]
Adjust:[***]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD:
1kHz/±1.5kHz)
1) Adj item:
[RSSI Reference
(Analog Narrow)]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD:
1kHz/±1.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenwood NX-5200 K2 and is the answer not in the manual?

Kenwood NX-5200 K2 Specifications

General IconGeneral
Frequency Range136-174 MHz
Operating Temperature-30°C to +60°C
Operating Voltage7.5V DC ±20%
GPSOptional
Ingress ProtectionIP67
MIL-STDMIL-STD-810 C/D/E/F/G
Power Output5W
WaterproofYes
Channel Spacing12.5 kHz / 25 kHz
Digital ProtocolNXDN
Modulation16K0F3E, 11K0F3E

Related product manuals