(No.RA018<Rev.002>)1-91
[P25
(C4FM)]
1) Adj item:
[P1 SQL]
Adjust:[***]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-1dB
(MOD: 1kHz/
±2.2kHz)
1) Adj item:
[Open Squelch (P25
C4FM)]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -1dB
(MOD: 1kHz/
±2.2kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[P25
(LSM)]
1) Adj item:
[P1 SQL]
Adjust:[***]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±3.3kHz)
1) Adj item:
[Open Squelch (P25
LSM)]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/
±3.3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[NXDN
Narrow]
1) Adj item:
[Nn SQL]
Adjust:[***]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-1dB
(MOD: 400Hz/
±2.5kHz)
1) Adj item:
[Open Squelch
(NXDN Narrow)]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -1dB
(MOD: 400Hz/
±2.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item Condition Measurement Adjustment Specifi-
cations
/Remarks
Panel tuning mode PC test mode Test-
equip-
ment
Unit Ter-
minal
Unit Parts Method

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenwood NX-5200 K2 and is the answer not in the manual?

Kenwood NX-5200 K2 Specifications

General IconGeneral
Frequency Range136-174 MHz
Operating Temperature-30°C to +60°C
Operating Voltage7.5V DC ±20%
GPSOptional
Ingress ProtectionIP67
MIL-STDMIL-STD-810 C/D/E/F/G
Power Output5W
WaterproofYes
Channel Spacing12.5 kHz / 25 kHz
Digital ProtocolNXDN
Modulation16K0F3E, 11K0F3E