Do you have a question about the Kenwood PS20-18 and is the answer not in the manual?
Brand | Kenwood |
---|---|
Model | PS20-18 |
Category | Power Supply |
Language | English |
Highlights compact size, light weight, and high efficiency due to the advanced switching method.
Features 7-segment red LED displays for easy checking of output voltage and current.
Stops switching and interrupts AC power relay when protection functions are active for overall safety.
Disables output by stopping switching if output voltage exceeds the set OVP value.
Interrupts AC power relay by stopping switching when output current exceeds rated levels.
Triggers AC power relay interruption when heat sink temperature reaches approximately 100°C.
Safeguards against input over-voltage or internal abnormalities by stopping output.
Generates an alarm signal to indicate protection activation and turn off the output.
Allows external signals to interrupt the power relay for user-side control or troubleshooting.
Minimizes input surge current upon initial power-on with a dedicated protection circuit.
Explains control functions for power/output switching and voltage/resistance mode selection via switch S1.
Compensates for voltage drops caused by load lines and contact resistance.
Features bright, easy-to-read red LED displays for simultaneous voltage and current readings.
Details electronic output switching and limit switch function for setting verification.
Provides detailed electrical, mechanical, and interface specifications for the GP-600 GP-IB adapter.
Compensates for voltage drops across load lines and contact resistance for precise output delivery.
Covers control of AC power relay ON/OFF and output ON/OFF via external signals.
Outputs voltage and current monitoring signals for external feedback and analysis.
Enables control of output voltage and current using external voltage or resistance inputs.
Details input signals for power, output, CV/CC modes, OVP, and alarm status.
Explains output signals for voltage, current, ON/OFF, power, OVP, and alarm status.
Lists CV parameters including Ripple, Line/Load Regulation, and Transient Response for all models.
Covers power source, display accuracy, protection, environmental conditions, and case dimensions.
Details CC parameters such as Ripple, Line/Load Regulation, and Input Current for various models.
Illustrates physical dimensions for Type I, Type II, and Type III case configurations.
Presents rack mount options (RK-600E) for integrating PS series units into standard racks.