Do you have a question about the Kenwood PS36-10 and is the answer not in the manual?
Brand | Kenwood |
---|---|
Model | PS36-10 |
Category | Power Supply |
Language | English |
Highlights the PS Series' compact and lightweight design, achieved through an advanced switching method for excellent space efficiency and high efficiency.
Output voltage and current are clearly indicated on 7-segment red LED displays for easy monitoring and checking.
Ensures safety by stopping switching operation and interrupting the AC power relay when a protection function is active.
Stops switching operation and turns off the output when the output voltage exceeds the OVP setting value.
Stops switching operation and interrupts AC power relay if output current exceeds 110% of the rated current.
Stops switching operation and interrupts AC power relay when the heat sink temperature reaches approximately 100°C.
Stops switching operation and turns off the output due to input over-voltage, voltage drop, or internal abnormality.
Generates an alarm signal to turn output off and interrupt AC power relay upon detecting OCP, OHP, or power off.
Allows the power relay to be interrupted by an external signal for user-side troubleshooting or issues.
Activates upon power-on to reduce the input surge current, protecting the power supply.
Uses an electronic switch system for silent operation, automatically set to off at power-on for safety.
Displays constant voltage and current limiting values for setting and verification without interrupting output.
Compensates for voltage drop caused by load connection resistance and contact resistance up to 1V per path.
Allows external control of the AC power relay on/off, provided the power switch is on.
Enables external signal control for turning the output on/off, or fixing it to on.
Provides monitoring outputs for voltage (0-1/10V) and current (0-10V) relative to rated values.
Allows output voltage and current control using an external voltage source (0-10V).
Enables output voltage and current control using an external resistance (0-10kΩ).
Details specifications for Ripple, Line regulation, Load regulation, and Transient response for CV mode.
Covers power source, display instruments, protection mechanisms, case dimensions, and accessories.
Details Overvoltage, Overcurrent, Overheating protection, thermal fuse, and input fuse functionalities.
Provides dimensions for Type I, Type II, and Type III cases, along with accessory information.
Illustrates the physical dimensions for case types I, II, and III, and the GP-600 unit.
Details the dimensions and types (1/2, 1/3, 1/6 rack width) of racks for the PS Series.