STEP #5
Electrical Connection
Before proceeding further, verify that the power supply is disconnected. Verify that the
appropriate electrical supply requirements have been met. Please refer to the table on
page 2 for appropriate electrical requirements. The cooktop is supplied with a 36-inch
long conduit for a connection to an accessible junction box. The 240V and 208V conduit
consists of three insulated wires. There are two insulated hot lead conductors (red and
black) and one insulated ground conductor (green). The 120V conduit consists of three
insulated wires. There is the hot lead conductor (black), the neutral conductor (white) and
one insulated ground conductor (green).
Attach conductor wires to residence wiring in accordance with national, state and local
electric codes.
Warning - Grounding
The entire appliance must be grounded at all times when the
electrical power supply is on. Do not ground the appliance with the
neutral house supply wire (white). A separate ground must be used.
6
STEP #6
Final Preparations Prior to Use
Removetheplasticlmfromthecooktop.Cleanthecooktopbeforeyouuseitfortherst
time. A thorough cleaning with a recommended cooktop cleaner (Cerama Brite Ceramic
Cooktop Cleaner) will provide a clean, shiny coating on the cooktop surface.
The next section of the manual covers cooktop use, maintenance, safety and service
information.
Please keep these instructions with the KENYON cooktop for future reference.
Name Plate
Label Location