K4C COMPACT-MULTI INSTALLATION/OPERATION MANUAL
K4C Compact-multi Feb-06
13
Horizontal Position
Top 6” (152 mm)
Front 24” (610 mm)
Rear - Front Breech 6” (152 mm)
Rear - Rear Breech 24” (610 mm)
Side - Non-Access 6” (152 mm)
Side - Access 24” (610 mm)
Return Air Side - Ductwork 1” (25 mm)
Flue Pipe 9” (229 mm)
Floor 6” (152 mm)
DRAFT PRESSURE
Breech draft pressure -0.04” wc
Overfire draft pressure
-0.01” wc
(Not Applicable to Direct Vent Units)
BURNER INSERTION (overall)
Riello 40F3 - BF3 & Beckett PA402 - 404 2 1/2” (63 mm)
AIR/BLOWER DATA
External static - Non AC 0.2” wc
External static - AC 0.5” wc
Cooling 3 tons
Maximum air temperature rise 85°F
High Limit, max design outlet temp. 200°F
Thermostat anticipator 0.2 amps
MOTOR/BLOWER 1/3 HP 4 Speed/GT 10 DD
FAN/HIGH LIMIT CONTROL
Honeywell L6064A1037 or L6064B1003, 11”
FAN CENTRE RELAY AC models only
Honeywell R8285A1048
White Rodgers 8A05A-101
DIMENSIONS
Depth 22 7/8” (581 mm)
Height 44 1/4” (1124 mm)
Width 19 1/2” (495 mm)
PLENUM DIMENSIONS
Cold air return 18 x 14 5/8” (457 x 371 mm)
Hot air supply 18 1/4 x 21 5/8” (464 x 549 mm)
Height to plenum 44” (1118 mm)
AC COIL LOCATION
Minimum height above the heat exchanger 4” (100 mm)