AIR/BLOWER DATA
External static – Non – A/C 0.2” wc
External static – A/C 0.5” wc
Cooling 4 tons
Maximum air temperature rise 85°F
High Limit, max design outlet temp 180°F
MOTOR/BLOWER
1 hp GE ECM/GT12DD
PLENUM DIMENSIONS
Cold air return 18 1/8” x 18 1/8” (460 x 460 mm)
Hot air supply 21 13/16” x 20 7/8” (554 x 530 mm)
Height to plenum 36 13/16” (supply) (935 mm)
39 13/16” (return) (1011 mm)
A/C COIL LOCATION
Minimum height above the cabinet 6” (152 mm)
See A/C coil Manufacturer’s Requirements
OPENING HEIGHTS from floor
Burner c/l 14 3/4” (375 mm)
Smoke pipe c/l 24 1/2” (622 mm)
DIMENSIONS
Depth 45 1/2” (1156 mm)
Height 39 13/16” (1011 mm)
Width 23” (584 mm)
Shipping Weight 398 lb (180 kg)
SMOKE/VENT PIPE 3” IPEX System 636
CLEANOUTS
Front Covers & Burner Opening
AIR FILTERS (All Models) Pleated 20” x 20” x 2”
THERMOSTAT (Digital)
Honeywell Focus Pro 5000 or similar
FUEL not heavier than No. 2 furnace oil.
ELECTRICAL – 120 Volts, 60 Hz
Canada Less than 12 amps.
USA 13.3 amp, circuit protection 20 amps.