PARAMETERS DESCRIPTION DEFAULT MIN. MAX. UNIT
7
SLOW DOWN
CLOSING SPEED
Motor speed during closing deceleration phase.
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1 * 1 5
7
SLOW DOWN
CLOSING SPEED
FASTLINE
Motor speed during closing deceleration phase.
1 = minimum
2 = low
3 = medium
1 1 3
8 STEP BY STEP
SBS conguration:
0 = Normal (OP-ST-CL-ST-OP-ST…)
1 = Alternate STOP (OP-ST-CL-OP-ST-CL…)
2 = Alternate (OP-CL-OP-CL…)
3 = Apartment block – timer (always opens)
4 = Apartment block with immediate reclosure
(always opens. Closes if gate is open)
0 0 4
9
MOTOR 2
DELAY
Leaf 2 opening delay with gate closed
0 - 60 sec.
2 0 60 s
9
MOTOR 2
DELAY
FASTLINE
(swing gate only)
Leaf 2 opening delay with gate closed 0 - 60
sec.
2 0 60 s
10
SLOW DOWN
LENGTH
Deceleration distance
0 = Customised decelerations
1 to 100 = Motor deceleration percentage
during opening and closure. With KUBE,
programmable deceleration during opening and
closure will be individually adjustable for each
engine
20 ** 0 100
% (step
of 1)
10
SLOW DOWN
LENGTH
FASTLINE
Deceleration distance
20 to 100 = Motor deceleration percentage
during opening and closure
20 5 100 % (step of 1)
11 ENERGY SAVING
Energy saving: enables photocell switch-o󰀨
when gate is closed
0= disabled
1= enabled
0 0 1
12 BLACK OUT
0 = OFF
1 = When the power line is restored, the motor
will automatically re-close
0 0 1
* For SUN4024 sliding gate motors the parameter will be DEFAULT 1 - MIN 1 - MAX 2