6.2 - RX4Y receiver
If necessary, users may select the RX4X RECEIVER MENU, used to
manage the parameters relating to the radio unit.
Proceed as follows
ADD TX Allows a new code to be memorised in the receiver
DELETE TX Allows deletion of a code from the receiver
DELETE ALL Clears the receiver’s entire memory
READ MEMORY Displays the codes in the memory
MEMORY LOCK/UNLOCK Unlocks or locks the receiver’s memory
ADDING A TX USING THE DISPLAY
This procedure allows one or more transmitters to be memorised in the receiver.
(WARNING: if there is not already at least one transmitter in the memory, the rst transmitter entered will establish the type of code -
rolling code or xed code).
1. Access the menu:
RX4Y
ADD TX
2. Select the type of channel in which the button is to be saved (CHANNEL 1= step by step; 2= parcial opening; 3= open; 4= lights on/
o󰀨; 5= memorisation of all 4 codes with preset functions as specied above). Press V to conrm.
3. Press the button of the TX to be memorised.
4. After the button is pressed, the display will show: TRANSMITTER MEMORISED.
5. To add another code, start the procedure again from point 2. To quit the menu, press “X”.
The “X” button is e󰀨ective at any point in the procedure.
If no commands are given for 10 seconds, the receiver automatically quits the memorisation mode.
DELETING A TX USING THE DISPLAY
This procedure allows a radio code to be deleted from the memory of the RX4Y receiver using the transmitter memorised.
1. Access the menu:
RX4Y
DELETE TX
2. Press the button of the TX to be deleted when prompted.
3. After the button is pressed, the display will show: TRANSMITTER DELETED.
4. To add another code, start the procedure again from point 2.
To quit the menu, press “X”. The “X” button is e󰀨ective at any point in the procedure.
If no commands are given for 10 seconds, the receiver automatically quits the memorisation mode.
CLEARING THE MEMORY OF THE RX4Y RECEIVER
This procedure is used to clear the entire memory of the receiver.
1. Access the menu:
RX4Y
CLEAR ALL
2. Conrm the request by pressing “V” or exit using “X”.
3. On conrmation, the display will show: MEMORY DELETED.
READING THE RECEIVER MEMORY
This procedure is used to view the radio codes present in the memory of the RX4Y receiver.
A
C
B
D
M = PRESET
FUNCTIONS
1. Access the menu:
RX4Y
READ MEMORY
2. Use and to scroll through the codes in the memory. The number of the transmitter in the memory, the
radio code saved and the relative button and channel will appear on the rst line of the display, while the second
line will indicate that the code can be deleted, conrming with V.
3. To quit the menu, press “X”. The “X” button is e󰀨ective at any point in the procedure.
MEMORY LOCK/UNLOCK
This procedure is used to lock or unlock the memory of the RX4Y receiver.
1. Access the menu:
RX4Y
MEMORY
LOCK/UNLOCK
0=OFF memory unlocked
1= ON memory locked
N.B. if the receiver is blocked by means of the XR MANAGER device, refer to the user manual of the latter.
14A