23
EN
4 - INSTALLING THE PRODUCT
WARNING - Before making the connections, ensure that the control unit is not powered up
4.1 - Electrical connections
COM
PAR
OPEN
CLOSE
SBS
NEG
PH-POW
PH1
PH2
COM
FLASH
LED
SEN
SHIELD
ANT
COM
STOP
EDGE
EDGE
COM
ELEC
COM
IND
POWER
SUPPLY
N
T2A
L
230Vac
50/60Hz
PHOTOTEST
LIGHT
TWILIGHT SENSOR
OUTPUT LED
STOP
OPEN
PHOTOCELL 1
PHOTOCELL 2
CLOSE
PARCIAL
STEP BY STEP
+ COMMON
+ COMMON
SAFETY
EDGE
ELECTRIC
LOCK
NEGATIVE
SBS
M1
M2
PH2
RX
COMMON
FLASH
PH1
RX
PH2
TX
PH1
TX
ECLIPSE
TWILIGHT SENSOR
FLASH
COM
LED
2
1
NEG POS
NEG POS
COM OUT
NC
2
1
NEG POS
NEG POS
COM OUT
NC
POWER SUPPLY CONNECTIONS
L Power supply 230 Vac 50-60 Hz
Earth
N Power supply neutral 230 Vac 50-60 Hz
M2 M2M1 M1
BATTERIES
(ACCESSORY)
TRANSFORMER