EasyManua.ls Logo

Key Automation 14A - Using the Display Programmer

Key Automation 14A
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
EN
N.B.: Only for
sliding gates
COM
PAR
OPEN
CLOSE
SBS
NEG
PH-POW
PH1
PH2
COM
FLASH
LED
SEN
SHIELD
ANT
COM
STOP
EDGE
EDGE
COM
ELEC
COM
IND
POWER
SUPPLY
2
3
4
1
1
2
TX
RX
NC
PH1
2
3
4
1
1
2
TX
RX
PH2
GND
_
12/24
AC/DC
GND
_
12/24
AC/DC
COM
OUT
GND
_
12/24
AC/DC
GND
_
12/24
AC/DC
COM
OUT
NC
N
T2A
L
230Vac
50/60Hz
PHOTOTEST
LIGHT
TWILIGHT SENSOR
OUTPUT LED
STOP
OPEN
PHOTOCELL 1
PHOTOCELL 2
CLOSE
PARCIAL
STEP BY STEP
+ COMMON
+ COMMON
SAFETY EDGE
ELECTRIC LOCK
NEGATIVE
SBS
M1
M2
BATTERIE
(ACCESSORIO)
COM
LED
FLASHSEN
COMMON
FLASH
ELECTRICAL CONNECTIONS
FOR ENERGY SAVING
PO24 POWER MODULE
(M1 - M2)
MA24 ELECTRIC CONNECTIONS
SHIELD Antenna - shield -
ANT Antenna - signal -
COM Common for FLASH, LED, SEN inputs / outputs
FLASH Flashing light output 24Vdc (without regulation) maximum 25W
LED
Courtesy light output 24Vdc (without regulation) maximum 15W (radio channel 4 selecting COURTESY LIGHT
START = 2, COURTESY LIGHT TIME = 0 )
SEN Ambient light sensor input
COM IND output common
IND Gate open warning light output, 24Vdc (without regulation) maximum 4W
COM ELEC output common
ELEC Electric lock output 12Vac, maximum 15VA
EDGE/EDGE Sensitive edge output, NC contact or resistive 8k2
COM STOP output common
STOP
Safety STOP NC contact between STOP and COM. This input is considered as a safety device; the contact may
be broken at any time, cutting out the automation at once and disabling all functions, including automatic closure.
EDGE Sensitive edge output, NC contact or resistive 8k2
NEG Photocell power supply negative output
PH-POW Photocell power supply positive output, 24Vdc (without regulation, maximum 250mA
PH1
Photocells (closure), NC contact between PH1 and COM. The photocell is tripped at any time during closure of the
automation, stopping movement at once and reversing the travel direction
PH2
Photocells (opening), NC contact between PH2 and COM. The photocell is tripped at any time during opening and
closure of the automation, stopping movement at once; the automation will continue opening when the contact is
restored if it was opening, or continue closing if it was closing (see parameter “PHOTO 2”)
COM Common for PAR, OPEN, CLOSE and SBS outputs
PAR
PARCIAL opening command, NO contact between PAR and COM
Used to open the gate partially, depending on the software setting
PO24 CONNECTIONS
LS1 Limit switch 1 input (only for SUN)
LS2 Limit switch 2 input (only for SUN)
V+ Limit switch / encoder power supply positive common (12 Vdc 50 mA MAX)
ENC Encoder S signal input
NEG Encoder power supply negative
M- Motor output
Earth
M+ Motor output
LS1
LS2
V +
ENC
NEG
M -
M +
M
ENCODER POWER
SUPPLY +
ENCODER POWER
SUPPLY -
ENCODER

Related product manuals