25
EN
25
   MIN MAX 
1
TCL
Automatic reclosure time (0 = off) 0 0 900 s
2
ttr

(0 = off)
0 0 30 s
3
SEI
Sensitivity on obstacles
0 = Maximum impact force
10 = Minimum impact force
3 0 10
4
SFO
Motor speed during opening
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
5
SSO
Motor speed during opening deceleration phase
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1 1 5
6
SFC
Motor speed during closing
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
7
SSC
Motor speed during closing deceleration phase
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1 1 5
8
SBS




3 = Apartment block – timer
4 = Apartment block with immediate reclosure
0 0 4
9
LSI
Deceleration distance
0 to 100 = Motor deceleration percentage during
opening and closure
20 0 100 %
10
BlT
Post blackout procedure
0 = No action, remains stationery
1 = Closure
0 0 1 s
11
SBY
Energy saving: enables photocell switch-off when gate
is closed
0= disabled
1= enabled
0 0 1