Do you have a question about the Keyence GV-21 and is the answer not in the manual?
Brand | Keyence |
---|---|
Model | GV-21 |
Category | Accessories |
Language | English |
General safety rules and warnings for laser products.
Describes the function of the laser radiation emission indicator.
Details the types and placement of laser warning labels.
Verifies all included parts upon receiving the product.
Instructions for mounting the sensor amplifier on a DIN rail.
Steps for connecting expansion units (GV-22/GV-22P) to the main unit.
Details the I/O cable connections for the sensor amplifier.
Identifies the key components of the sensor head.
Steps to connect the sensor head connector to the amplifier.
Guidance on mounting the sensor head, including bracket usage.
Specific mounting advice for different target detection situations.
Labels and identifies the various parts of the sensor amplifier.
Explains the different screens and indicators on the amplifier.
How to interpret setting, current, peak, and bottom value displays.
Details how the current value relates to workpiece distance and resolution.
Steps to calibrate using workpiece and non-workpiece points.
Using DATUM method for calibration based on a reference surface.
Adjusting the sensor's setting value for optimal performance.
Explains Distance and DATUM detection methods.
Explains the A-1 Edge hold mode for detecting workpieces with height changes.
Covers 2-point, Max Sensitivity, Full Auto, and 2-point Area calibration.
Steps for 2-point calibration in F-1, A-1, A-2 modes.
Performing calibration with a moving target.
Procedure for 1-point area calibration in F-2 mode.
Steps for DATUM calibration and how to clear it.
Restores factory defaults and manages custom settings.
Covers bank switching and zero point positioning.
Procedure to enable or disable the keylock function.
Adjusting the sensor's response time.
Configuring control output modes (N.O./N.C.).
Choosing between Normal, Area, Edge Hold, and Surface detection modes.
Handling situations where distance detection fails.
Configuring delay timers for control outputs.
Adjusting hysteresis for control output judgments.
Assigning functions to the external input pin.
Setting the time for sensor detection value stabilization.
Sets the control output mode for each control output.
Sets the operation mode (Normal, Area, Edge, Surface).
Operations when distance detection cannot be performed.
Individual delay timers for channels 1 and 2.
Sets hysteresis for judgment with control outputs.
Assigns functions to the external input (pink line).
Shifts the current value by another amount.
Sets side close to sensor head as positive/negative direction.
Reduces consumption current or stops displaying values.
Addresses issues like incorrect output and non-functioning external input.
Illustrates output and input circuits for the sensor amplifier.
Details specifications for various sensor head models.
Details specifications for sensor amplifier models.
Covers KEYENCE's warranty terms and limitations.
Requirements for reselling or delivering products to third parties.