EasyManuals Logo

Keyence IV-500C User Manual

Default Icon
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
IV Series (Sensor) - IM_E
Vision Sensor
IV-500C / IV-500CA /
IV-500M / IV-500MA /
IV-150M / IV-150MA /
IV-2000M / IV-2000MA
Instruction Manual
Read this manual before using the product in order to
achieve maximum performance.
Keep this manual in a safe place after reading it so that it
can be used at any time.
For details of functions, refer to the IV Series User's Manual
(Monitor) or the IV Series User's Manual (PC).
The IV Series User's Manual can be downloaded from the
KEYENCE web site:
http://www.keyence.com/
Symbols
The following symbols alert you to important messages.
Be sure to read these messages carefully.
It indicates a hazardous situation which, if not
avoided, will result in death or serious injury.
It indicates a hazardous situation which, if
not avoided, could result in death or serious
injury.
It indicates a hazardous situation which, if not
avoided, could result in minor or moderate
injury.
It indicates a situation which, if not avoided,
could result in product damage as well as
property damage.
It indicates cautions and limitations that must
be followed during operation.
It indicates additional information on proper
operation.
It indicates tips for better understanding or useful
information.
Cautions
(1) Unauthorized reproduction of this manual in whole or
part is prohibited.
(2) The contents of this manual may be changed for
improvements without prior notice.
(3)
An utmost effort has been made to ensure the contents of
this manual are as complete as possible. If there are any
mistakes or questions, please contact a KEYENCE ofce
listed in the back of the manual.
(4) Regardless of item (3), KEYENCE will not be liable for
any effect resulting from the use of this unit.
(5) Any manuals with missing pages or other paging faults
will be replaced.
The company names and product names used in this
manual are registered trademarks or the trademarks of their
respective companies.
Safety Information for IV series
General Precautions
Do not use this product for the purpose to
protect a human body or a part of human body.
This product is not intended for use as an
explosion-proof product. Do not use this
product in a hazardous location and/or
potentially explosive atmosphere.
You must verify that the IV Series are
operating correctly in terms of functionality
and performance before the start and the
operation of the IV Series.
We recommend that you take substantial
safety measures to avoid any damage in the
event of a problem occurring.
KEYENCE never warrants the function or
performance of the IV Series if it is used in manner
that differs from the IV Series specications
contained in this instruction manual or if the IV
Series are modied by yourself.
When the IV Series is used in combination with
other instruments, functions and performance
may be degraded, depending on operating
conditions and the surrounding environment.
Do not place the instruments, including
peripherals, under rapid temperature
change. It may cause condensation and may
damage instruments or peripherals.
Remove the power cable from the power supply
if you do not use this product for a long time.
Important Instructions
Observe the following precautions to prevent malfunction of
the IV Series and to ensure that it is used properly.
Precautions on use
The power of this product and instruments
connected to this product must be turned off
when the cable is to be installed or removed.
Failure to do so may cause an electric shock
or a product damage.
Use this product in the correct supply voltage.
Failure to do so may cause a product damage.
96M12230

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keyence IV-500C and is the answer not in the manual?

Keyence IV-500C Specifications

General IconGeneral
BrandKeyence
ModelIV-500C
CategoryAccessories
LanguageEnglish

Related product manuals