iButton Series Programming Guide Section: Programming Guide Non-Software
How to program an existing 'iButton' user with a scheduled access time restriction
Example: A business wants to grant an existing iButton user access Monday, Wednesday,
Friday between 8:30am and 5:30pm. (remember, 24 hr time)
Enter: #23456#45# <Touch iButton to reader> + 135#08301730#
#23456# 45# Touch iButton 135# 0830 1730#
Master Code Function code User iButton Mon/Wed/Fri Start time End Time
Keyless Enty Locks For current prices, please visit our website. www.KeylessEntyLocks.com
46 Danada Sq West #4133 Phone: (630) 909-9504
Wheaton, IL 60189 Page 18 of 58 FAX: (630) 447-3635