Firmware Upgrade Guide N5191-90023 7
Firmware Upgrade Guide
Step 3. Connect the Signal Generator to the PC
Using LAN
Connect the signal generator to the PC:
Either
use a 100 Base-T LAN cable to connect the signal generator to the PC,
or
connect both the PC and the signal generator to the LAN using 100 Base-T LAN cables.
There are numerous ways to configure the signal generator to connect to the LAN. Refer to:
Keysight MXG FAQ’s “How do I connect the Keysight MXG Signal Generator to a PC using
LAN?”.
Keysight Technologies IO Libraries USB/LAN/GPIB Interfaces Connectivity Guide (E2094–
90009).
Keysight X-Series Programming Guide or,
http://www.keysight.com/find/uxg
Depending on the signal generator's current LAN settings and which procedure you choose, the
signal generator's LAN settings may be changed. Since these settings are persistent (retained
through presets and power cycles) it is recommended that you record the current LAN settings so
you can restore them back to their original settings after upgrading the firmware. Information on
the LAN softkeys is provided in key Help of the instrument. See also the User’s Guide.
Using GPIB
1. Connect a GPIB cable between the PC and the signal generator.
2. Set the GPIB address:
Press Utility > I/O Config > GPIB Setup > GPIB Address > 19
The signal generator’s GPIB address is set to 19 at the factory. The acceptable range of
addresses is 0 through 30. Once initialized, the state of the GPIB address is not affected by a
signal generator preset or by a power cycle. Other instruments on the GPIB cannot use the
same address as the signal generator.
Using USB
Connect a USB cable between the PC and the signal generator’s rear panel Micro USB connector.
If the “Found New Hardware” wizard activates, select Install the Software Automatically.
If there is more than one signal generator on the same bus whose GPIB address is 19, turn the
power off to the instrument(s) or change the address of the signal generator of interest.

Other manuals for Keysight Technologies N5193A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N5193A and is the answer not in the manual?

Keysight Technologies N5193A Specifications

General IconGeneral
BrandKeysight Technologies
ModelN5193A
CategoryPortable Generator
LanguageEnglish

Related product manuals