Loading...
Keysight X-Series Signal Generators Error Messages 141
Error Messages
List of Error Messages
search algorithm exceeded the allowable limit. This event indicates
an unstable power level. The power will be set to the last properly
leveled power.
640 WB I/Q Settings conflict; I/Q and WB I/Q cannot be on at the same time:
Mux I/Q path and WB I/Q path cannot be on simultaneously
The modulation types I/Q and WB I/Q cannot be used at the same
time. This error is reported when the user attempts to activate one
type of modulation while the other is activated. The modulation
type that was most recently requested will be turned on and the
modulation that was on at the time will be turned off.
640 WB I/Q Settings conflict; WB I/Q and AM WB cannot be on at the same
time: Mux I/Q path and WB I/Q path cannot be on simultaneously
The modulation types I/Q and AM WB cannot be used at the same time.
This error is reported when the user attempts to activate one type
of modulation while the other is activated. The modulation type
that was most recently requested will be turned on and the
modulation that was on at the time will be turned off.
641 File header error; Could not perform header operation on '{name}'
There was a problem performing a header operation on the given
file.
642 Security error; Security level cannot be decreased since instrument is
already in secure mode.
This error occurs when trying to change the security level to a
less secure one and instrument is already in secure mode. The level