Keysight U1271A/U1272A Quick Start Guide 15
Keysight U1271A/U1272A Quick Start Guide 15
ENGLISH
Diode tests
Set up your multimeter as shown in the figure
below to perform diode tests.
Auto-diode tests (U1272A only):
The Auto-diode function tests both the
forward bias and reverse bias directions of
your diode simultaneously. The forward bias
voltage is shown on the primary display and
the reverse bias voltage is shown on the
secondary display.
Press until is shown on
the display to use the auto diode
function.