The Danfoss compressor requires approximately 11.0 Volts (12 Volt System) or 23.0 Volts
(24V System) to operate. If the voltage drops below this, the fridge will stop running.
Cable Specification
The DC cables must have a suitable cross-section for their length, according to this table:
*Note: The length is from the battery to the refrigerator.
Cable Area
12V Max Cable Length* 24V Max Cable Length*
[mm2]
AWG
[m]
[ft.]
[m]
[ft.]
2.5
13
2.5
8
5
16
4
11
4
13
8
26
6
9
6
20
12
39
10
7
10
33
20
66
2
DC SOCKET
AC
~
100-240V
12V ANDERSON SOCKET
Operation
Power
The electronic control module powers the compressor motor and has the function of a
three stage battery protection. When the input voltage drops below the minimum, the
compressor will cut out; when the voltage comes back up to the cut-in value, the
compressor will restart automatically.