1. Alarm and Operation Audible and Visual Indicators
Operational Mode Visual Indications
Audible
Indications
Description:
Normal operation Red LED blinks every 60s.
Temperature change
over 10 mins > +/-
3°C
Notification on mobile app only Temperature dropping or
rising quickly.
Low temperature
alarm (below
3°C / 37°F)
Red LED blinks every 3s. Loud beep
every 3s.
Temperature could start
freezing pipes.
See Section 7 for alarm timing
information.
Water detected
alarm
Red LED blinks every 3s. Loud beep
every 3s.
Water has been detected at the
alarming unit.
See Section 7 for alarm timing
information.
Alarm Hush Red LED blinks every 15s.
Device in alarm mode with sounder silenced
NOTE: If an alarm is not Hushed in the first
60 seconds, Hush might be delayed by
up to 30 seconds as the detector waits to
communicate with the cloud.
Low Battery
Red LED blinks every 60s. Chirp every 60s. Inform the user it is time to change the
batteries.