EasyManua.ls Logo

Kidde 900-CUAR - Troubleshooting Guide

Kidde 900-CUAR
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
4. Troubleshooting Guide
3. Other Alarm Visual And Audible Indicators
If you require further information please contact Product Support at 1-800-880-6788 or write us at:
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302. Our internet address is www.kidde.com.
Trouble Condition
Visual Indications Audible Indications Action
False Low Battery
(AC power
connected before
backup batteries
activated)
Amber LED blinks
every 60 sec.
Chirp every 60 sec. * Pull the battery pull tab to activate the backup
batteries.
Low Battery Amber LED blinks every
60 sec.
Chirp every 60 sec. * Push button once to silence for 24 hrs.
(Pushbutton again to clear Hush
TM
and perform
a test.)
Note: 7 days after Low Battery begins, the
notications cannot be silenced.
* Replace batteries as soon as possible.
Photo Fault Amber LED blinks every
60 sec.
3 chirps every 60 sec. * See Cleaning Your Alarm section.
* Push button once to attempt to reset the unit.
* If error continues, remove alarm, dispose unit,
and replace as soon as possible.
CO Fault Amber LED blinks 2 times
every 60 sec.
3 chirps every 60 sec. * Push button once to attempt to reset the unit.
* If error continues, remove alarm, dispose unit,
and replace as soon as possible.
Memory Fault Amber LED blinks 3 times
every 60 sec.
3 chirps every 60 sec. * Push button once to attempt to reset the unit.
* If error continues, remove alarm, dispose unit,
and replace as soon as possible.
End of Unit Life Amber LED blinks 2 times
every 60 sec.
2 chirps every 60 sec. * Push button once to silence for 24 hrs. (Push
button again to clear Hush
TM
and perform
a test.)
Note: 7 days after End of Unit Life begins, the
notications cannot be silenced.
* Remove alarm, dispose unit, and replace as
soon as possible.
MCU Failure None Constant Tone * Remove alarm, dispose unit, and
replace as soon as possible.
Stuck Button Amber LED blinks 4 times
every 60 sec.
3 chirps every 60 sec. * Push button to dislodge it from being stuck.
If button cannot be unstuck, remove alarm,
dispose unit, and replace as soon as possible.

Other manuals for Kidde 900-CUAR