Control panel accessories
Table 4: Control panel accessories
Model
Description
VM-REMICA
Remote Paging Microphone: Provides remote paging capability throughout a building or
campus. Each VM-REMICA has two inputs for connecting other remote microphone units.
The paging circuit supports up to 63 interconnected remote paging stations. See installation
sheet P/N 387466 for specifications.
R
-Series /
K
-R-Series
remote
annunciat
or
Remote annunciators: Provide status indication and common controls for the control panel.
The following annunciators and interface cards can be used with the VM-1 fire alarm control
panel.
RLCD-C / K-RLCD-C Remote Annunciator: Provides LCD
text annunciation with common
controls. See installation and operation guide P/N 3101969-EN for specifications.
RLCD / K-RLCD Remote Annunciator: Provides LCD text annunciation without common
controls. See installation and operation guide P/N 3101969-EN for specifications.
RLED-C / K-RLED-C Remote Annunciator: Provides LED zone annunciation with
common controls. See installation and operation guide P/N 3101969-EN for
specifications.
RLED24 / K-RLED24 Remote Annunciator Expander: Provides 24 red-over-yellow pairs
of LEDs (12 pairs configurable as yellow-over-yellow). See installation and operation
guide P/N 3101969-EN for specifications.
GCI and GCI-NB Graphic Annunciator Interface Cards: Connect a compatible UL/ULC
Listed fire alarm control panel to an LED-based graphic annunciator. See installation
sheet P/N 3100973-EN for specifications.
GCIX Graphic Annunciator Expander Card: Provides additional switch inputs and LED
outputs on GCI(-NB) card-based graphic annunciators. See installation sheet P/N
3101296-EN for specifications.
G
SA-REL Releasing Module: Actuates solenoid valves that control the release of water or chemical
e
xtinguishing agents in support of fire suppression applications such as sprinkler systems and
automatic fire extinguishing systems. See technical reference manual P/N 387515 for
specifications.
RPM
Reverse Polarity Module: Provides three reverse polarity transmitters: one for system
common alarm; one for system common trouble; and one for system common supervisory.
Installs on a half-footprint space on the CAB6B backbox. See installation sheet P/N 3100430
for specifications.
SIGA-AA30
30-watt audio amplifier: Dual input, switch mode amplifier capable of producing a 25 or 70
VRMS audio signal from a 1 or 25 VRMS input. See installation sheet P/N 387343-ML for
specifications.
SIGA
-AA50 50-watt audio amplifier: Dual input, switch mode amplifier capable of producing a 25 or 70
VRMS audio signal from a 1 or 25 VRMS input. See installation sheet P/N 387343-ML for
specifications.
CTM
City Tie Module: Provides a single municipal box connection for activating a local e
nergy type
master box that is connected to a public fire alarm reporting system. See installation sheet
P/N 3101025 for specifications.
3-TAMP
Tamper Switch: Detects an open VM-1 control panel door. Installs on the CAB6B backbox.
See installation sheet P/N 387422 for specifications.