EasyManuals Logo

Kikusui PLZ164W Quick Reference

Kikusui PLZ164W
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
LOAD
1
LOAD key
Turns the load on and off. The LED lights
when the load is on and turns off when the
load is off.
2
MODE key
Sets the operation mode.
+CV (SHIFT + MODE) key
Adds CV to CC or CR mode.
3
SET/VSET key
Sets the fundamental settings (current/
conductance/voltage/power).
MENU (SHIFT + SET/VSET) key
Used to set features and environment
settings, calibrate the PLZ, and display
product information.
4
RANGE key
Sets the range (L/M/H).
VRANGE (SHIFT + RANGE) key
Switches the voltage value range (15 V/150
V).
5
SLEW RATE key
Sets the slew rate value.
SHORT (SHIFT + SLEW RATE) key
Activates or deactivates the short function.
6
OPP/OCP key
Sets the power at which OPP is activated or
the current at which OCP is activated.
UVP (SHIFT + OPP/OCP) key
Sets the voltage at which UVP is activated.
PRESET/SEQ
10
RECALL key
Recalls the saved panel settings into the
setup memory.
STORE (SHIFT + RECALL) key
Saves the panel settings to the setup memory.
11
ENTER key
Sets various values and releases alarms.
ABC (SHIFT + ENTER) key
Saves the panel settings to the preset
memory. After you press this key, press the
A, B, or C key.
12
A key
Recalls the settings in preset memory A.
When this key is pressed after the ABC key,
it saves the settings.
EDIT (SHIFT + A) key
Displays the sequence editing screen.
13
B key
Recalls the settings in preset memory B.
When this key is pressed after the ABC key,
it saves the settings.
RUN/STOP (SHIFT + B) key
Displays the sequence screen. Starts and
stops sequence execution.
14
C key
Recalls the settings in preset memory C.
When this key is pressed after the ABC key,
it saves the settings.
PAUSE (SHIFT + C) key
Temporarily stops or restarts sequences.
You can download the most recent manuals from the following website.
http://www.kikusui.co.jp/en
Quick Reference
PLZ
-
4W Series
* Red keys are lighted.
31
22
23
32
30
29
28
27
26
24 25
Main Specications
Ratings
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating voltage (DC)
1
1.5 V to 150 V
2
0 V to 150 V
3
Current 33 A 66 A 200 A 33 A 132 A
Power 165 W 330 W 1000 W 165 W 660 W
1.
Minimum voltage at which the current starts flowing to the PLZ-4W is approximately 0.3 V.
2.
The minimum operating voltage (including the voltage drop due to the wire inductance component) in switching mode
increases by 0.15 V per 1 A/μs at slew rate settings greater than 5 A/μs.
3.
The minimum operating voltage (including the voltage drop due to the wire inductance component) in switching mode
increases by 0.3 V per 1 A/μs at slew rate settings greater than 5 A/μs.
Constant Current Mode (CC)
Model
Range
PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range H 0 A to 33 A 0 A to 66 A 0 A to 200 A 0 A to 33 A 0 A to 132 A
M 0 A to 3.3 A 0 A to 6.6 A 0 A to 20 A 0 A to 3.3 A 0 A to 13.2 A
L 0 A to 330 mA 0 A to 660 mA 0 A to 2 A 0 A to 330 mA 0 A to 1.32 A
Accuracy of setting H, M ± ( 0.2 % of set + 0.1 % of f.s
1
) + Vin
2
/500 kΩ
L ± ( 0.2 % of set + 0.1 % of f.s )
Input voltage
variation
3
H 2 mA 4 mA 10 mA 2 mA 8 mA
M 2 mA 4 mA 10 mA 2 mA 8 mA
L 0.1 mA 0.2 mA 0.6 mA 0.1 mA 0.4 mA
1.
Full scale of H range
2.
Vin: Input terminal voltage of Electronic Load
3.
When the input voltage is varied from 1.5 V to 150 V at a current of rated power/150 V.
Constant Resistance Mode (CR)
Model
Range
PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range
1
H 22 S to 400 μS 44 S to 800 μS
133.332 S to 2.4 mS
22 S to 400 μS 88 S to 1.6 mS
M 2.2 S to 40 μS 4.4 S to 80 μS
13.3332 S to 240 μS
2.2 S to 40 μS 8.8 S to 160 μS
L 0.22 S to 4 μS 0.44 S to 8 μS 1.33332 S to 24 μS 0.22 S to 4 μS 0.88 S to 16 μS
Accuracy of setting
2
H, M ±(0.5 % of set
3
+ 0.5 % of f.s
4
) + Vin
5
/500 kΩ
L ± (0.5 % of set
3
+ 0.5 % of f.s)
1.
Conductance [S] = Input current [A]/input voltage [V] = 1/resistance [Ω]
2.
Converted value at the input current. At the sensing point.
3.
set = Vin/Rset
4.
Full scale of H range
5.
Vin: Input terminal voltage of Electronic Load
Constant Voltage Mode (CV)
Model
Range
PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range H 1.5 V to 150 V 0 V to 150 V
L 1.5 V to 15 V 0 V to 15 V
Accuracy of setting
1
--- ±(0.1 % of set + 0.1 % of f.s)
Input current variation
2
--- 12 mV
1.
At the sensing point during remote sensing under the operating range of the input voltage.
2.
With respect to a change in the current of 10 % to 100 % of the rating at an input voltage of 1.5 V (during remote sensing).
Constant Power Mode (CP)
Model
Range
PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range H 16.5 W to 165 W 33 W to 330 W 100 W to 1000 W 16.5 W to 165 W 66 W to 660 W
M 1.65 W to 16.5 W 3.3 W to 33 W 10 W to 100 W 1.65 W to 16.5 W 6.6 W to 66 W
L 0.165 W to 1.65 W 0.33 W to 3.3 W 1 W to 10 W 0.165 W to 1.65 W 0.66 W to 6.6 W
Accuracy of setting
--- ±(0.6 % of set + 1.4 % of f.s
1
)
1.
M range applies to the full scale of H range.
General
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Input voltage range 100 Vac to 240 Vac
(90 Vac to 250 Vac) single phase, continuous
100 Vac to 120 Vac/200 Vac to 240 Vac
(90 Vac to 132 Vac/180 Vac to 250 Vac)
single phase
Input frequency range 47 Hz to 63 Hz
Power consumption 80 VA max. 90 VA max. 160 VA max. 450 VA max. 1500 VA max.
SWITCHING
7
SW ON key
Turns switching mode on and off.
8
FREQ/DUTY key
Sets the switching frequency or the duty
ratio.
Th/TL (SHIFT+FREQ/DUTY) key
Sets the switching time (Th: HIGH/TL:
LOW).
9
LEVEL key
Sets the switching level. The key lights
when the level can be set.
% (SHIFT + LEVEL) key
Sets the switching level as a percentage of
the set value (0 % to 100 %).
Miscellaneous
15
Rotary knob
Changes the settings. Press the knob to
switch between coarse and fine adjustment.
Contrast (SHIFT + knob)
Adjusts the contrast of the display.
16
key
The up key.
INS (SHIFT+ ) key
Adds a step (sequence function).
17
key
The down key.
DEL (SHIFT+ ) key
Deletes a step (sequence function).
18
key
The left key.
PREV (SHIFT+ ) key
Returns to the previous screen.
19
key
The right key.
NEXT (SHIFT+ ) key
Switches to the next screen.
20
LOCAL key
Switches from remote mode to local mode.
LOCK (SHIFT + LOCAL) key
Enables or disables the key lock.
21
SHIFT key
Enables the functions displayed in blue
below the keys.
Display
22
Range display
Displays the current and voltage ranges.
23
(key icon)
Appears when the key lock is enabled.
24
(remote icon)
Appears during external communication.
25
(COARSE/FINE icon)
Indicates whether the rotary knob is set to
coarse or fine adjustment.
26
Measured value display
Indicates the measured values (current,
voltage, and power).
27
Operation status display
Displays the current operation mode.
28
Elapsed time display
Displays the amount of time that has
elapsed since the load was turned on.
29
Operation mode display
Displays the set operation mode.
30
Setting display
Displays the set value.
31
(short icon)
Appears when the short function is being
executed.
32
Multi display
Displays various settings and statuses.
Chapter 3
For First Time Users
6.6
Sequence Function
6.7
Remote Sensing Function
6.8
External Control
6.9
Monitor Signal Output
6.10
Parallel Operation
8.1
Maintenance
8.2
Confirming Status of the Fuse
8.3
Calibration
8.4
Malfunctions and Causes
Chapter 9
Specifications
The Users Manual (contained in the accompanying CD-ROM)
contains the following additional information.
In the appendix, there are explanations of the operation modes and the operating area and a sequence program creation table.
For information about remote control, see the communication interface manual (contained in the accompanying CD-ROM).
Z1-004-802, IB020572
Oct. 2015
1
15
10 11
12 13 14
LOAD
SWITCHING PRESET/SEQ
Display
2 3 4 5 6
7 8 9
16
18
17
19
20
21

Other manuals for Kikusui PLZ164W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kikusui PLZ164W and is the answer not in the manual?

Kikusui PLZ164W Specifications

General IconGeneral
BrandKikusui
ModelPLZ164W
CategoryPower Supply
LanguageEnglish

Related product manuals