SECTION 2
INSTALLATION OF FIRE
2.1 UNPACKING THE COMBUSTION CHAMBER
Carefully lift the combustion chamber out of the carton. Remove the loose item
packaging carefully from the pack. Check the contents as listed :-
DO NOT UNDER ANY CIRCUMSTANCES USE THIS APPLIANCE IF THE
GLASS PANEL IS BROKEN OR NOT SECURELY FIXED TO THE FIREBOX.
Packing Check List
1 off Combustion Chamber & Glass Frame Assembly
1 off Trim (packed in front section of combustion chamber pack)
1 off Boxed ceramic fuel-bed set (packed inside combustion chamber)
1 off 125mm flue spigot adaptor (packed inside combustion chamber)
1 off Flue terminal assembly (packed inside combustion chamber)
1 off Draught diverter assembly (packed inside combustion chamber)
1 off Installation Instruction Manual
1 off User Instruction Manual
1 off Length of foil tape
1 off Handset & 1 off 9V Battery
1 off 20mm mounting frame & 4 off 10mm x 4mm mounting frame screws
1 off Loose Items pack containing :-
4 off No. 12 x 40mm Screws
4 off Rawlplugs
4 off Adjustable screw-in feet
IMPORTANT NOTE BEFORE PROCEEDING WITH THE INSTALLATION
This product requires a minimum effective flue height of 4.0 metres of minimum
circular cross-sectional area 125mm. If installing the product into a 225mm x
225mm brick chimney, THE CHIMNEY SOUNDNESS MUST BE CHECKED BY
TESTING prior to a decision being made on whether the chimney requires lining.
If the flue height is greater than 10 metres on an external wall or 12 metres on an
internal wall then a flue liner must be fitted even if the chimney integrity is ok
.
Please check the chimney height and integrity prior to proceeding with the
installation, to establish if a chimney liner is required. Any flue pipe should
conform to BS 715 / BS EN 1856-2 (Metal flue pipes for gas appliances).
When you have decided upon if the product requires the fitting of a flue
liner, proceed with the creation of the correct sized builders opening or
studwork installation of the product as per sections 2.2 or 2.3
6