5.0 Start ( this step is MUST):
Send to the RTU5034 for adjust the time.
E.g.: 1234TEL00861351015# 00861351015 is the SIM card number which inside of the RTU5034.
Return: Set Success!
Notice
If the RTU5034 cannot working well in the exactly time, then send the SMS command to adjust time
manually as below:
Send to the RTU5034 for adjust the time manually.
E.g.: 1234T 1601131300#
T:Command Code.
Current Time: yy(year)mm(month)dd(day)hh(hour)mm(minute).
Return: Set Time OK!
5.1 Change Password
E.g.: 1234P6666 for change the new password to 6666.
Return: “Password changed to 6666, please remember it carefully.” if password changed successfully.
5.2 Authorized User number managerment
5.2.0 Add authorized user:
A:command code.
serial number: the authorized users position, from 001~200.
start time:yy(year)mm(month)dd(day)hh(hour)mm(minute).the start time of this number can call in to control.
end time: yy(year)mm(month)dd(day)hh(hour)mm(minute).the end time of this number can call in to control.
Without start time and end time means: Always can call in to control.
E.g.: 1234A003#123456# to set the phone no.123456 at the 3
rd
position and always can call in to control.
E.g.: 1234A016#123456#1502050800#1502051000# to set the phone number 123456 at the 16
th
position,
this number can call in to control during Feb 5
th
8:00a.m.(1502050800) to Feb 5
th
10:00a.m.(1502051000).
Note: 1. The authorized number means the one who can dial the RTU5034 to control the relay.
2. The Serial Number is the position to store the authorized users, from 001~200.
5.2.1 Inquiry the Authorized user’s position(serial):
E.g.: 1234A002# to check the number on the 2
nd
position(serial number2).
pwdTELphone number of the RTU5034#
pwd Tcurrent time
1234Pnew password
pwdA serial number # phone number # start time # end time #
pwdAserial number#