EasyManua.ls Logo

King Pigeon RTU5034 - 5.2.2 Inquiry Batch Users Number; 5.2.3 Delete Authorized Users Number; 5.3 Relay Control Settings; 5.3.1 Allow All Numbers to Control

King Pigeon RTU5034
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
_________________________________________________________________________________________
Page
8
of
11
Ver 1.7 File No.:RTU5034103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.4G-RTU.com Support@GSM-Gate-Opener.com
5.2.2 Inquiry batch users number
E.g.: 1234AL002#050# to inquiry the authorized numbers from the 2
nd
to the 50
th
,RTU5034 return several
SMS with the numbers list(10 numbers on each SMS).
5.2.3 Delete the Authorized Users Number(or you can overwrite this position with another number).
E.g.: 1234A002## to delete the 2
nd
authorized number.
5.3 Relay Control setting
5.3.1 Allow all numbers can call in to control:
5.3.2 Allow only the authorized numbers can call in to control(Caller-ID for security, default):
5.3.3 How long time the relay keep close(ON) after phone call in (unit: second)
close time=000~999. Unit: Second
close time=000: relay close 0.5 second then open (use the relay as Latch).
close time=999: relay will always keep close(ON) after call in until the next call in.
E.g.: 1234GOT030# to set relay close 30 seconds(ON) and then open(OFF) after call in.
5.3.4 Who will receive the confirmation SMS when the relay is ON/OFF
for relay ON, for relay OFF.
ab: the ID code of the 1
st
number(a) and the caller number(b), =0 means disable, =1 means enable.
content: confirmation SMS content.
ID code
RTU5034 send notify SMS to
a
b
The 1
st
number
Caller number
0
0
0
1
1
0
1
1
E.g.: 1234GON11#Door Open#
The 1
st
number & the caller number receive confirmation SMS when relay is ON(door opened).
E.g.: 1234GOFF00#Door Close#
The 1
st
number & the caller number will not receive confirmation SMS when relay is OFF(door closed)..
5.3.5 No need confirmation SMS when the relay is ON/OFF.
pwdALserial number start#serial number end#
pwdAserial number##
pwdALL#
pwdAUT#
pwdGOTclose time#
pwdGOFFab#content#
pwdGONab#content#

Related product manuals