5.2.2 Inquiry batch users number
E.g.: 1234AL002#050# to inquiry the authorized numbers from the 2
nd
to the 50
th
,RTU5034 return several
SMS with the numbers list(10 numbers on each SMS).
5.2.3 Delete the Authorized User’s Number(or you can overwrite this position with another number).
E.g.: 1234A002## to delete the 2
nd
authorized number.
5.3 Relay Control setting
5.3.1 Allow all numbers can call in to control:
5.3.2 Allow only the authorized numbers can call in to control(Caller-ID for security, default):
5.3.3 How long time the relay keep close(ON) after phone call in (unit: second)
close time=000~999. Unit: Second
close time=000: relay close 0.5 second then open (use the relay as Latch).
close time=999: relay will always keep close(ON) after call in until the next call in.
E.g.: 1234GOT030# to set relay close 30 seconds(ON) and then open(OFF) after call in.
5.3.4 Who will receive the confirmation SMS when the relay is ON/OFF
for relay ON, for relay OFF.
ab: the ID code of the 1
st
number(a) and the caller number(b), =0 means disable, =1 means enable.
content: confirmation SMS content.
RTU5034 send notify SMS to
E.g.: 1234GON11#Door Open#
The 1
st
number & the caller number receive confirmation SMS when relay is ON(door opened).
E.g.: 1234GOFF00#Door Close#
The 1
st
number & the caller number will not receive confirmation SMS when relay is OFF(door closed)..
5.3.5 No need confirmation SMS when the relay is ON/OFF.
pwdALserial number start#serial number end#