5
KINNEY
®
KT SERIES MANUAL 1843-1
© 2003, Tuthill Corporation
INTRODUCTION
This manual applies to Kinney Vacuum models KT-150, KT-300, KT-500 and KT-850. You should be thoroughly
familiar with these instructions before attempting to install, operate or repair this unit. Consult Tuthill Vacuum &
Blower Systems when problems arise that cannot be resolved after reading this manual. Always include pump
nameplate information when ordering parts or components.
SPECIFICATIONS
KT-150 KT-300 KT-500 KT-850
Free Air
Displacement
CFM
m³/h
150
255
300
510
490
840
780
1325
Pump Speed (rpm) RPM 1055 870 721 581
Motor speed at 50
Hz
RPM 1,500 1,500 1,500 1,500
Motor speed at 60
Hz
RPM 1,800 1,800 1,800 1,800
Motor Power HP 7.5 15 30 40
Oil Capacity (total/
refill)
US gal.
Liters
6/5
23/19
10/8.5
38/32
15/12.5
57/47
28/25
106/95
Cooling water at
60° F (16° C)
Gpm
L/min
1/4 1.5/6 2.5/9 3.5/13
Cooling Water Inlet Inch
NPT
1/4” 3/8” 3/8” 3/8”
Suction, 150 lb.
ANSI Flanged
3 4 6 8
Discharge, 150 lb.
ANSI Flanged
2 3 4 5
Height w/o oil mist
eliminator
Inches
mm
43
1092
51
1295
63
1600
71
1803
Floor Space Inches
mm
24x26
609x660
27x34
686x864
34x38
864x965
38x49
965x1245
Weight Lbs
Kg
800
363
1,525
692
2,625
1,191
4,175
1,894
Ultimate
Pressure
Microns 10 10 10 10
Noise Level
(Typical at 10 Torr)
dBA 71 72 73 75