5.4 AC Load Management
The generator has the following receptacles:
1- 240V/50A 14-50R
-13-
1- 120V/20A 5-20R duplex
1- 120V/30A L5-30R twistlock
Maximum load from the various receptacles is as follows:
- 240V AC at 25 amps is available from the 50A receptacle. Connecting this receptacle to a 50A
service receptacle will allow 25 amps @ 120 volts to two separate legs.
- 25 amps from the L5-30R twist lock receptacle
- 25 amps from the duplex receptacle.
Simultaneous operation of 120 and 240 volt appliances is possible but the total amperage of the
applied loads cannot exceed the generator receptacle rating.
Under no circumstances will the generator permit any AC load greater than 25 amps to any one
receptacle.
NOTE
When an electric motor is started, both the overload indicator light (red) and the output indicator light
(green) lights may go on simultaneously. This is normal if the overload indicator light (red) goes off
after about four (4) seconds. If the overload indicator light (red) stays on, consult you dealer.