EasyManua.ls Logo

KitchenAid Gas cooktop - Gas supply requirements; Installation must conform with state or other codes; Provide a gas supply line of 3;4 rigid pipe; Use A.G.A.-certified, new flexible metal tubing

KitchenAid Gas cooktop
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When installina two cookto~s. use the
following width dimension:’ ’
Two cooktops
I
Cutout Width
I -I
23” min
All other dimensions remain the same
for all cutouts:
Cutout depth: 20-l/2”
Cutout to front of countertop: l-1/2” min.
Cutout to backsplash
or rear wall: l-1/2” min.
Cutout to combustible surface: 3-l/2”
Gas supply
requirements
Observe all governing codes and ordinances.
Explosion Hazard
Use a new AGA approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person
make sure gas pressure does not exceed
14” water column. Examples of a qualified
person include licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death,
explosion, or fire.
IAl
This installation must conform with state
or other codes or, in the absence of
. such codes, with the Standard for
Recreational Vehicles, ANSI Al 19.2.‘*
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
IBI
Input ratings shown on the model/serial
. rating plate are for elevations up to
2,000 feet. For elevations above 2,000
feet ratings are reduced at a rate of 4% for each
1,000 feet above sea level.
El
Provide a gas supply line of 3/4” rigid
. pipe to the cooktop location. A smaller
size pipe on long runs may result in
insufficient gas supply. Pipe-joint compounds
made for use with L.P. gas must be used.
IDI
If local codes and ordinances permit,
n
A.G.A.-design-certified, new flexible
metal tubing is recommended for
connecting cooktop to the gas supply line. Do Not
kink or damage the flexible tubing when moving
the cooktop. A l/2” male pipe thread is needed
for connection to pressure regulator female pipe
threads.
shutoff valve
El
The supply line shall be equipped with
. an approved shutoff valve. This valve
should be located in the same room as
the cooktop and should be in a location that
allows ease of opening and closing. Do Not block
access to shutoff valve. The valve is for turning
on or shutting off gas to the appliance.
IF’
If rigid pipe is
L-l usedasagas
n n
supply line, a
combination of pipe
fittings must be used to
obtain an in-line
connection to the cook-top. All strains must be
removed from the supply and fuel lines so
cooktop will be level and in line.
El
The regulator must be checked at a
. minimum 1” water column above the set
pressure. The inlet pressure to the
regulator should be a s follows for operation and
checking the regulator setting:
L.P. GAS:
Set pressure 10 inches W.C.
Maximum pressure 14 inches W.C.
4