7. If something does not work
All repair and maintenance work must be done exclusively by Klafs or by a dealer we
expressly authorize!
Error Cause Remedy
The control
system cannot be
switched On.
No mains voltage. Check the FI-switch and the fuse in the mains
supply.
The control
system can not be
started in standby
mode.
The safety temperature limiter
(STL) tripped.
Do not operate the control system.
Inform Klafs Service.
The cabin light
does not turn On.
The main switch of the
control system is not
switched On.
Switch On the main switch at the control
system.
Bulb defective. Change the bulb.
Procedure: separate the control system from
mains.
Replace with a bulb of the same wattage.
No mains voltage. Check the FI-switch and the fuse in the mains
supply.
Fuse SI100 cut out. Change the fuse SI100 (1.25 AT) or inform
Klafs Service.
8. Maintenance and Cleaning
The humidity during sauna operation does not harm the wood of your cabin. Without fail, the cabin
must be aired out properly.
Never hose down inner cabin walls, bench or seats with water or a high pressure cleaner!
Recommendation: Cleaning the sauna cabin with cabin light.
. Prerequisite: Turn the controller of the bathing temperature all the way to the left.
Switch On the main switch at the control system.
Switch On light switch.
Dirty benches
Wipe the wooden surfaces with a damp cloth.
If necessary, sand the upper side of the benches with fine sandpaper.
The benches can also be washed off with a 3 %‐hydrogen peroxide solution (available in specialized
stores).
Disinfectants are highly corrosive!
Therefore, pay attention to the relevant safety regulations!
Use household rubber gloves!
The outer cabin walls are impregnated or glazed.
In no case glaze, paint or impregnate the inner panelling or the cabin inner walls and