INSTALLATION INSTRUCTIONS FOR BUILT-IN
The following instructions are directed at the qualied installer, so the installation
and maintenance procedures may be followed in the most professional and expert
manner.
Important: Unplug the electrical connection before performing any maintenance
or regular upkeep work.
Positioning for gas hob
Important: this unit may be installed and used only in permanently ventilated
rooms.
The following requirements must be observed:
1. The room must be tted with a ventilation system which ventilates smoke and
gases from combustion to the outside of rooms. This must be done by hood
or electric ventilator.
In a chimney stack or branched
ue (exclusively for cooking
appliances).
Directly to the outside.
2. The room must be allowed for the inux of the air which is for proper
combustion. The air ow for combustion purposes must not less than 2 m³/h
per kW of installed capacity. The air supply will be eected by inux from the
outside through a duct, its inner cross section is at least 100 cm² and must not
be blocked accidentally.
The gas hob without safety devices, to prevent ame go out accidentally, must
have a ventilation working on twice volume. For example, a minimum of 200
cm² (Fig. 3). Otherwise, the room can be vented indirectly through adjacent
rooms which is tted with ventilation ducts to the outside. Although the
adjacent rooms are not shared areas, bedrooms, but re risk is hidden (see
illustration).