62
EN
TABLE 2: How to convert gas source
Burners Flame Converting the
hob from LPG
to natural gas
Converting the
hob from natural
gas to LPG.
Regular burners Full ame Replace the
burner nozzle
according to the
guidelines in
Table 1.
Replace the
burner Nozzle
according to the
guidelines in
Table 1.
Saving ame Loosen the
adjustment.
Spindle (see g.
below)
And adjust the
ame.
Loosen the
adjustment.
Spindle (see g.
below)
And adjust the
ame.
Valve adjustment
Valve adjustment should be done with the control knob set at Burner ON saving
ame position.
Remove the knob, and adjust the ame with a tiny screwdriver (see g. below).
To check the adjusted ame: heat the burner at full open position for 10 minutes.
Then turn the knob into the saving setting. The ame should not extinguish nor
move to the nozzle. If it extinguish or moves to the nozzle, readjust the valves.