Introduction to PLC System Connection

Overview of PLC System Connection

Describes how the PLC system connects to operator terminals via SUCOM-A protocol.

Driver Installation and Updates

Installation via Internet

Instructions for updating or installing drivers using MAC Programmer+ via the internet.

Installation from Disk

Instructions for updating or installing drivers using MAC Programmer+ from a disk.

Terminal to PLC System Connection

MAC Programmer+ Configuration

Steps to configure communication settings within the MAC Programmer+ software.

Communication Setup

Details on setting up the communication port and parameters between terminal and PLC.

Driver Transfer to Terminal

Process for transferring the driver to the terminal using Project Transfer.

PLC System Settings

Reference to PLC system settings required for communication.

Physical Connection

Guidance on physical point-to-point connection methods and cable configurations.

Addressing and Error Handling

Digital and Analog Object Addressing

Explanation and addressing schemes for digital and analog data types.

Maximum Address Limits

Specifies maximum address limits for various Klockner Moeller PS4 controllers.

Error Messages

Details error messages and their meanings for PS4 series controllers.

Optimizing Communication Efficiency

Signals Affecting Communication Time

Details signals that impact communication speed and those that do not.

Methods for Efficient Communication

Provides strategies to enhance communication speed and efficiency.

Connection Drawings and Pinouts

RS-232 and RS-422 Pin Configurations

Details pin assignments for RS-232 and RS-422 connections across various MAC models.

Cable Connection Diagrams

Illustrates specific cable layouts and connections for terminals and PCs.

Cable CAB5;3 m Connection Details

Specifics of the CAB5/3m cable connecting the operator terminal to the PC.

Cable CAB12 Connection Details

Specifics of the CAB12 cable connecting PC to E-terminal.

Klockner Moeller PS4-341-MM1 Specifications

General IconGeneral
Product brand nameKlockner Moeller
Product designationPS4-341-MM1
Supply voltage24 V DC
Digital inputs14
Digital outputs10
Analog inputs2
Analog outputs2
Protection ClassIP20
Communication interfaceRS-232, RS-485
Operating Temperature0°C to 55°C