SERVICE MANUAL
34 30APR96 – SM4530-1
[12] Manually move the CLAMP PAD ASSEMBLY until the TAB is in the NULL position.
Warning
Dangerous Voltage
[13] Connect the main power.
Important
It is necessary to make a FAN COVER TOOL. See the Tools section.
[14] Install the FAN COVER TOOL over the FAN area and the LAMP MODULE. See the Tools section.
[15] Install and hold the AUTO FOCUS TARGET SLIDE TL-3002 until it is fully seated in the GATE MECHANISM.
[16] Set the projector to the LO-LAMP position.
[17] Observe the image of the focus light path on the bottom of the FAN CAP; the light path should be in the center
of the hole in the FAN CAP.
[18] Bend the CLAMP PAD ASSEMBLY until the image is in the center of the hole in the FAN CAP.
[19] Assemble the PHOTOCELL MASK, FILTERS and PHOTOCELL BOARD.
A091_4027BA
A091_4027BCA
light path
PAD
CLAMP LEVER
TAB
NULL position
A091_4030BA
AUTO-FOCUS
TARGET SLIDE
TL-3002
T-BAR TL-3003
light image
FAN CAP
CLAMP PAD
ASSEMBLY
A091_4030BCA
hole