on connected battery type.
When “SBU” or “SOL” is set as output source priority and battery
voltage is lower than this setting voltage, unit will transfer to line mode
and the grid will provide power to load.
Back to discharge
voltage
When “SBU” or “SOL” is set as output source priority and battery
voltage is higher than this setting voltage, battery will be allowed to
discharge.
To configure charger source priority.
It’s to set up battery charging parameters. The selectable values in
different inverter model may vary.
Please see product manual for the details.
Max. AC charging
current:
It’s to set up battery charging parameters. The selectable values in
different inverter model may vary. Please see product manual for the
details.
Enable or disable battery equalization function.
Real-time
Activate Battery
Equalization
It’s real-time action to activate battery equalization.
To set up the duration time for battery equalization.
To set up the extended time to continue battery equalization.
To set up the frequency for battery equalization.
To set up the battery equalization voltage.
LCD Auto-return
to Main screen
If enable, LCD screen will return to its main screen after one minute
automatically.
If enabled, fault code will be recorded in the inverter when any fault
happens.
If disabled, LCD backlight will be off when panel button is not operated
for 1 minute.
If enabled, unit will transfer to line mode when overload happened in
battery mode.
Beeps while
primary source
interrupt
If enabled, buzzer will alarm when primary source is abnormal.
Over
Temperature
Auto Restart
If disabled, the unit won't be restarted after over-temperature fault is
solved.
If disabled, the unit won’t be restarted after overload occurs.
If disabled, buzzer won’t be on when alarm/fault occurred.