42 A-61818 April 2014
Document Feeder
Timeout: allows you to select the amount of time the scanner will
wait once the last document enters the feeder before the timeout
occurs.
Action when timeout occurs: indicates the action that will be taken
when the document feeder timeout has been reached.
- Stop Scanning: scanning will stop and control will return to the
scanning application (e.g., ends the job).
Sheet Counter — enter the number to be assigned to the next physical
sheet of paper entering the scanner. This is incremented sequentially
by the scanner and is returned in the image header.
Document Management
Intelligent Protection — allows you to select how aggressively the
scanner detects documents that enter the scanner incorrectly. This can
occur when documents are not prepared properly for scanning (e.g.,
stapled or paper clipped documents).
(none)
Minimum: select this option if the scanner is stopping too frequently
on documents that you do not want it to detect.
NOTE: Documents may become more damaged before detection
occurs.
Normal: this is the recommended option as it provides a balance
between minimizing document damage and stopping the scanner
unnecessarily.
Maximum: select this option to get the least amount of document
damage.
NOTE: This may cause the scanner to stop unnecessarily.
Maximum Length — select a value that indicates the length of the
longest document in your document set.
NOTES:
Changing this value will affect the maximums for the following
settings: Image Size - Outline; Multifeed - Length Detection.
Not all combinations of settings for Scan as and Resolution are
supported at the larger lengths. To allow for greater flexibility with
applications, the scanner will not generate an error until it sees a
document whose length is not supported.
The scanner's throughput may be reduced for large lengths.
Diagnostics — displays the Diagnostics tab.