Model No’s HOPC**MN2, HOPC**SN2, HOPC**TN2 & HOPC**RN2 are
for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B.
/ I.E.
** denotes variant of trim / fascia where applicable

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Kohlangaz Gosford Plus and is the answer not in the manual?

Summary

Section 1 Information and Requirements

1.0 Appliance Information

Details specific to the appliance model, gas type, and manufacturer.

1.1 Conditions of Installation

Legal and regulatory requirements for installing the fire.

1.2 Flue and Chimney Suitability

Specifies requirements for chimneys and flues compatible with the appliance.

1.3 Fireplace;Surround Suitability

Guidelines for suitable fireplace openings and surround materials.

1.4 Shelf Position

Specifies minimum clearance distances for shelves above the fire.

1.5 Flue;Chimney Inspection

Procedure for inspecting the chimney and flue before installation.

1.6 Fireplace Opening and Catchment Space

Dimensions and requirements for the fireplace opening and space.

1.7 Fitting to Pre-fabricated Metal Flue Boxes

Instructions for connecting the appliance to metal flue boxes.

1.8 Hearths

Requirements for the hearth material, thickness, and dimensions.

1.9 Spillage Monitoring System

Information and warnings about the spillage monitoring system.

Section 2 Installation of Fire

2.1 Unpacking the Fire

Checklist for unpacking the appliance and its components.

2.2 Installing the Fire Box

Steps for fitting the fire box into the fireplace opening.

2.3 Gas Tightness and Inlet Pressure (Manual Control Models)

Procedure for checking gas tightness and inlet pressure for manual controls.

2.4 Gas Tightness and Inlet Pressure (Slide Control Models)

Procedure for checking gas tightness and inlet pressure for slide controls.

2.5 Gas Tightness and Inlet Pressure (Remote;Electronic Control Models)

Procedure for checking gas tightness and inlet pressure for remote/EFC controls.

Section 3 Assembling Fuel Bed and Commissioning

3.1 Assembling the Ceramics and Fuel Bed

Detailed instructions for placing the ceramic fuel bed and coals.

3.2 Fixing the Infrared Sensor

Guidance on positioning the infrared sensor for remote control models.

3.3 Connecting the Battery Pack

Steps for connecting the battery pack for remote control functions.

3.4 Fitting the Trim

Instructions on how to attach the decorative trim.

3.5 Fitting the Fender

Instructions on how to position the fender.

3.6 Lighting the Appliance (Manual Control Models)

Step-by-step guide to lighting the fire with manual controls.

3.7 Lighting the Appliance (Slide Control Models)

Step-by-step guide to lighting the fire with slide controls.

3.8 Lighting the Appliance (Remote Control Models)

Step-by-step guide to lighting the fire with a remote control.

3.9 Lighting the Appliance (Electronic Fire Control Models)

Step-by-step guide to lighting the fire with electronic controls.

3.10 Checking for Clearance of Combustion Products

Procedure for testing flue gas spillage.

Section 4 Maintenance

4.1 Removing the Burner Assembly

Detailed steps for removing the burner assembly.

4.2 Removing the Piezo Igniter

Procedure for removing and replacing the piezo igniter.

4.3 Removing the Control Tap

Steps for removing and refitting the control tap.

4.4 Removing the Oxy-Pilot Assembly

Guidance on removing the oxy-pilot assembly.

4.5 Burner Assembly Removal (Slide Control Models)

Specific steps for burner removal in slide control models.

4.6 Removing the Battery Ignitor

Procedure for removing the battery ignitor.

4.7 Replacing the Battery (Slide Control Models)

Instructions for replacing the battery in slide control models.

4.8 Removing the Oxy-Pilot Assembly

Steps for removing the oxy-pilot assembly.

4.9 Replacing the Control Cable

Steps for replacing the control cable.

4.10 Burner Assembly Removal (Remote & Electronic Control Models)

Burner removal for Remote & Electronic Fire Control Models.

4.11 Removing the Valve Assembly

Procedure for removing the valve assembly.

4.12 Removing the Pilot Assembly

Guidance on removing the pilot assembly.

4.13 Replacing the Batteries (Within the Firebox)

Steps for replacing batteries in RC/EFC models.

4.14 Removing the Trim Switch

Procedure for removing the trim switch.

Section 5 User Instruction Section

5.1 Installation Information

Recap of installation conditions and safety notes for users.

5.2 Operating the Fire (Manual Control Models)

Instructions for operating the fire using manual controls.

5.3 Operating the Fire (Slide Control Models)

Instructions for operating the fire using slide controls.

5.4 Operating the Fire (Remote Control)

Instructions for operating the fire with a remote control handset.

5.5 Lighting the Appliance (Electronic Fire Control Models)

Instructions for operating the fire with electronic controls.

5.6 Turning Off in Malfunction

Procedure for emergency shut-off due to control malfunction.

5.7 Replacing Batteries (Remote;Electronic Control)

Steps for replacing batteries in RC/EFC models.

5.8 Replacing Battery (Slide Control Models)

Steps for replacing the battery in slide control models.

5.9 Spillage Monitoring System

Explanation of the spillage monitoring system and troubleshooting.

5.10 Cleaning

Safety precautions and instructions for cleaning the fire.

5.11 Assembling Fuel Bed & Ceramics

Instructions for re-assembling the fuel bed and ceramics.

Kohlangaz Gosford Plus Specifications

General IconGeneral
BrandKohlangaz
ModelGosford Plus
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals