78 TP-7044 6/23
Fuel System Bleed Procedure (14-24EKOZD/12-20.5EFKOZD Models)
1. Loosen the fuel filter’s air vent screw. See Figure 35. Place a suitable container underneath to collect the fuel.
2. Initiate the auto/start sequence until fuel, free of air bubbles, flows from the vent screw at the fuel filter.
3. Tighten the fuel filter’s air vent screw.
Figure 35 Fuel Filter’s Air Vent Screw
4. Check that the generator set is OFF.
5. Reconnect the generator set engine starting battery, negative (-) lead last.
6. Reconnect the power to the battery charger, if equipped.
Fuel filter’s air vent screw location