Perform these maintenance procedures more frequently under extremely dusty, dirty conditions.
2
Have a Kohler Engine Service Dealer perform this service.
3
Must be performed by an Authorized Kohler Engine Dealer or quali ed LPG personnel only.
Maintenance Instructions
Normal maintenance, replacement or repair of emission control devices and systems may be performed by any
repair establishment or individual; however, warranty repairs must be performed by a Kohler authorized
service center.
For safety and health reasons, many states require special licensing or certi cation for servicing LPG/NG fuel
systems. Check local and state regulations before choosing a repair establishment to perform fuel system repairs.
WARNING: Accidental Starts!
Disabling engine. Accidental starting can cause severe injury or death. Before working on the engine or equipment,
disable the engine as follows: 1) Disconnect the spark plug lead(s). 2) Disconnect negative (-) ba ery cable from ba ery.
Before disconnecting the negative (-) ground cable, make sure all switches are o . If on, a spark will occur at the ground cable
terminal which could cause an explosion if hydrogen gas or LPG/NG fuel vapors are present.
Maintenance Schedule
These required maintenance procedures should be performed at the frequency stated in the table. They should
also be included as part of any seasonal tune-up.
Frequency Maintenance Required
Daily or Before
Starting Engine
Check fuel gauge on propane (LPG) tank.
Check oil level.
Check air cleaner for dirty
1
, loose, or damaged parts.
Check air intake and cooling areas, clean as necessary
1
.
Every 25 Hours
Service precleaner element
1
.
Every 100
Hours
Replace air cleaner element
1
.
Change oil.
Remove cooling shrouds and clean cooling areas
1
.
Check oil cooler ns, clean as necessary (if equipped).
Check spark plug condition and gap.
Every 200
Hours
Change oil lter.
Annually or
Every 300
Hours
Replace spark plugs.
Annually or
Every 500
Hours
Check all lines (high pressure/vacuum) including ings for leaks.
Have electric starter serviced
2
.
Have lock-o / lter serviced
3
.
Have combustion deposits removed if using non-synthetic oil.
Drain regulator of accumulated fuel deposits (Nikki regulators only).
Every 1500
Hours
Have regulator disassembled, cleaned, and reset
3
.
Have vaporizer disassembled, cleaned, and serviced