8.5
Section 8
Disassembly
8
Figure 8-15. Oil Sentry
Switch Location in
Closure Plate.
Remove Baffles and Intake Manifold
1. Remove the screws securing the valley baffles to
the cylinder heads and backing shroud assembly.
Figure 8-18. Removing Intake Manifold.
Remove Oil Sentry
(If Equipped)
1. Disconnect the lead from the Oil Sentry
switch.
2. Remove the Oil Sentry
switch from the closure
plate. See Figure 8-15.
Figure 8-16. Removing Valley Baffles.
Figure 8-17. Removing Outer Cylinder Baffles.
3. Remove the four hex flange screws securing the
intake manifold to the cylinder heads. Cut any
wire ties that secure the wiring harness or leads
to the intake manifold.
4. Remove the intake manifold and gaskets. See
Figure 8-18.
Pressure
Switch
2. Remove the four screws securing each of the
outer cylinder baffles in place. Two of the screws
are accessed from the backing shroud side. See
Figure 8-17.
Mounting
Screws
Mounting
Locations
Mounting
Locations