10.16
Section 10
Reassembly
Figure 10-60. Attaching Recti er-Regulator Plug.
1&5
2
3
4
Figure 10-57. Tightening Short Screws for Outer
Baf es.
3. Insert and tighten all remaining blower housing
and ba e screws with the exception of the
recti er-regulator grounding bracket screw.
Torque all blower housing and ba e M6 screws
assembled into aluminum to 10.7 N·m (95 in. lb.)
for a new hole, or 7.3 N·m (65 in. lb.) for a used
hole. Torque all blower housing and ba e M5
screws assembled into sheet metal (backing plate)
to 2.8 N·m (25 in. lb.) for new holes, or 2.3 N·m
(20 in. lb.) for used holes.
4. Torque the four breather cover screws to
11.3 N·m (100 in. lb.) into new holes or 7.3 N·m
(65 in. lb.) into used holes in the sequence shown
in Figure 10-58. Note the rst screw is torqued a
second time.
Figure 10-58. Breather Cover Fastener Torque
Sequence.
Install Reconnect Recti er-Regulator
1. Install the recti er-regulator in the blower
housing if removed previously, then secure
grounding bracket against the outer side of the
recti er-regulator with a silver screw. See Figure
10-59.
Figure 10-59. Recti er-Regulator Ground Details.
2. Torque the two black recti er-regulator hex
ange screws to 1.4 N·m (12.6 in. lb.) and the
silver ground strap hex ange screw to
2.8 N·m (25 in. lb.) into new holes or 2.3 N·m
(20 in. lb.) into used holes.
3. Connect the plug to the recti er-regulator. If the
purple wire was removed, verify the locking tang
is raised on the terminal and push the wire
terminal into the plug prior to connecting to the
recti er-regulator. See Figure 10-60.
NOTE: The recti er-regulator middle terminal (B+)
is o set (not equally spaced) from the outer
terminals (AC). Verify the recti er-regulator
plug is assembled to match the terminal
o set of the recti er-regulator.
Silver Screw
Grounding
Strap