10.16
Section 10
Reassembly
Figure 10-60. Attaching Rectifi er-Regulator Plug.
1&5
2
3
4
Figure 10-57. Tightening Short Screws for Outer
Baffl es.
3. Insert and tighten all remaining blower housing
and baffl e screws with the exception of the
rectifi er-regulator grounding bracket screw.
Torque all blower housing and baffl e M6 screws
assembled into aluminum to 10.7 N·m (95 in. lb.)
for a new hole, or 7.3 N·m (65 in. lb.) for a used
hole. Torque all blower housing and baffl e M5
screws assembled into sheet metal (backing plate)
to 2.8 N·m (25 in. lb.) for new holes, or 2.3 N·m
(20 in. lb.) for used holes.
4. Torque the four breather cover screws to
11.3 N·m (100 in. lb.) into new holes or 7.3 N·m
(65 in. lb.) into used holes in the sequence shown
in Figure 10-58. Note the fi rst screw is torqued a
second time.
Figure 10-58. Breather Cover Fastener Torque
Sequence.
Install Reconnect Rectifi er-Regulator
1. Install the rectifi er-regulator in the blower
housing if removed previously, then secure
grounding bracket against the outer side of the
rectifi er-regulator with a silver screw. See Figure
10-59.
Figure 10-59. Rectifi er-Regulator Ground Details.
2. Torque the two black rectifi er-regulator hex
fl ange screws to 1.4 N·m (12.6 in. lb.) and the
silver ground strap hex fl ange screw to
2.8 N·m (25 in. lb.) into new holes or 2.3 N·m
(20 in. lb.) into used holes.
3. Connect the plug to the rectifi er-regulator. If the
purple wire was removed, verify the locking tang
is raised on the terminal and push the wire
terminal into the plug prior to connecting to the
rectifi er-regulator. See Figure 10-60.
NOTE: The rectifi er-regulator middle terminal (B+)
is off set (not equally spaced) from the outer
terminals (AC). Verify the rectifi er-regulator
plug is assembled to match the terminal
off set of the rectifi er-regulator.
Silver Screw
Grounding