Homeowners Guide
Bath with Airjets
K-1112, K-1114, K-1122,
K-1124, K-1151, K-1160,
K-1162, K-1164, K-1244,
K-1257, K-1337, K-1357
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de M corresponden a México
(Ej. K-12345M)
Français, page “Français-1”
Español, página “Español-1”
1034591-5-J

Other manuals for Kohler K-1112

Questions and Answers

  • M
    Michael DuncanAug 10, 2025
    What to do if my Kohler Kitchen & Bath Fixtures whirlpool stops automatically?
    • K
      kelly90Aug 11, 2025
      If your Kohler Kitchen & Bath Fixtures whirlpool stops automatically, it may be due to several reasons. The GFCI might be tripping, in which case you should identify and correct the source of the fault. A blocked suction requires removing the obstruction. Blocked jets also need the obstruction removed. If the motor overheated, check for blockages at the motor vents, suction, or jets; remove any blockages and allow the motor to cool.
  • H
    heather38Aug 17, 2025
    How to fix a Kohler Kitchen & Bath Fixtures whirlpool that does not start or stop?
    • D
      Dan TaylorAug 17, 2025
      If your Kohler Kitchen & Bath Fixtures whirlpool isn't starting or stopping, there could be a few reasons. First, ensure there is power to the motor by setting/resetting the GFCI breaker and checking the wiring. If the air actuator isn't working, consider replacing it and check the air tube between the air actuator and the pump. Finally, if the motor/pump isn't functioning, you might need to rebuild or replace it.
  • C
    Courtney StephensonAug 23, 2025
    Why is my Kohler Kitchen & Bath Fixtures heater not working?
    • P
      Patrick RamirezAug 23, 2025
      If the heater in your Kohler Kitchen & Bath Fixtures isn't operating, there are a few potential causes. First, check that there is power to the heater by resetting the GFCI. If the water temperature exceeds 104°F (40°C), allow the water to cool, and the heater will re-engage. If neither of these is the issue, the heater itself may need to be replaced.
  • A
    Adam TaylorAug 28, 2025
    What to do if motor starts, but all jets are not functioning in my Kohler Kitchen & Bath Fixtures?
    • L
      Linda LeeAug 28, 2025
      If the motor in your Kohler Kitchen & Bath Fixtures is running but the jets aren't working, it could be due to a couple of issues. First, check if the jet is closed, and if so, rotate the jet trim ring counterclockwise to open it. Alternatively, the jets might be blocked, in which case you should remove the blockage.
  • R
    Ralph EspinozaSep 4, 2025
    How to reduce noisy operation in Kohler Kitchen & Bath Fixtures?
    • T
      tiffanysandersSep 4, 2025
      If your Kohler Kitchen & Bath Fixtures is operating noisily, it might be because the pump banding straps haven't been cut. Cut the pump banding straps with tin snips.