Troubleshooting (cont.)
Troubleshooting Table
Symptoms Probable Cause Recommended Action
C. Pressure difference greater than
5 psi (34.5 kPa) between the hot
and cold supply lines.
C. Install pressure regulators to bring
supply lines within 5 psi (34.5 kPa)
of each other.
D. If none of the above actions
correct the symptom, the valve
requires servicing.
D. Contact your authorized Kohler
service representative.
7. Maximum blend
temperature too hot or
too cold.
A. Incorrect maximum temperature
setting.
A. Refer to the User Interface
Homeowners Guide.
B. If none of the above actions
correct the symptom, the valve
requires servicing.
B. Contact your authorized Kohler
service representative.
8. Continuous flow. A. System will not switch off. A. Turn off the water and power
supply and contact your authorized
Kohler service representative.
9. Water leaking from the
valve.
CAUTION: Risk of
personal injury or
product damage. Turn off
the main power and
water supply.
A. Connections not secure. A. Check all connections. Make
adjustments as needed.
B. Seals are worn or damaged. B. Order a seal service pack and
replace all seals.
C. Internal leak. C. Unit requires overhaul. Contact
your authorized Kohler service
representative.
10. Massage mode shuts
down but water continues
to run from
showerhead(s).
A. Unequal flow rates between
valve outlets.
A. Revise installation to have one
bodyspray per valve outlet. Use
bodysprays with the same flow
rate.
B. Fluctuation of the inlet water
pressure.
B. Install pressure regulators in the
supply lines.
C. Pressure difference greater than
5 psi (34.5 kPa) between the hot
and cold supplies.
C. Install pressure regulators to bring
supply lines within 5 psi (34.5 kPa)
of each other.
11. Hot water only, the valve
shuts down.
A. Hot and cold lines are reversed. A. Switch hot and cold water supply
connections. Verify the hot water
supply is connected to the inlet
marked H and the cold water
supply is connected to the inlet
marked C.
1043183-5-B 6 Kohler Co.