8.3 Generating set identification
The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
power level
(D):
Maximum power
(E):
Nominal power
(F):
Power factor
(G):
Ground
(H):
Current amperage
(I):
Current frequency
(J):
Current voltage
(K):
Protection rating
(L):
Reference standard
(M):
Serial number
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
Engine manufacturer:(e.g.
Kohler)
Engine serial number: (e.g Kohler (SERIAL
NO. 4001200908))
……/………….. - ……..………..….…. - ………
……..……..………..….…..….
……..………..….….……..………..….….
8.4 Specifications
Model
DIESEL 4000 C5
Maximum power
3400 W
Rated output
2720 W
Acoustic pressure at 1 m
92 dB(A)
Measurement uncertainty
0,7 dB(A)
Engine type
KD350_C5
Maintenance kit
RKDS1
Recommended fuel
Diesel
Fuel tank capacity
4,3 L
Recommended oil
15W40
Oil sump capacity
1,2 L
Oil cut-out*
X
Direct current
X
Alternating current
230V-11,8A
Circuit breaker(s)**
O
Socket type
2x2P+T-230V-10/16A
Battery
x
Dimensions l x w x h
81 x 55,5 x 59 cm
Weight (without fuel)
70 kg
o: standard
x: not available
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the
event of an overload and/or short circuit, the supply of electrical energy may be cut. If necessary, replace the circuit breakers in the generating set
with circuit breakers with identical nominal ratings and specifications.
8.5 Recommended fuel quality
Using fuel which does not comply with the following specifications risks causing irreversible damage not covered under the
warranty:
- Cleanliness and quality: ensure that the diesel used does not contain water, that it is new and clean (not out of date or
contaminated).
- Specifications: ASTM D975 - 1D or 2D, EN590 or equivalent.
- Outdoor temperature below 0°C: use a special fuel (for more information, please contact one of our agents).
However, it is strongly recommended that the same type of fuel is used throughout the complete service life of the unit. If the unit is
used infrequently (less than once a month), use new fuel with each use or add a stabilizing additive to the fuel tank.