SEN00459-01 40 Troubleshooting
10 114E-3 Series
E-6 Code [132/CA132] Throttle Sensor Low Error 1
Error code Failure code
Trouble Abnormally low level in throttle sensor power
132 CA132
Contents of
trouble
Low voltage is detected in fuel control dial signal circuit.
Action of con-
troller
Depends on machine model.
Problem that
appears on
machine
Depends on machine model.
Related infor-
mation
Method of reproducing failure code: Starting switch ON.
Possible causes
and standard
value in normal
state
Causes Standard value in normal state/Remarks on troubleshooting
1
Defective throttle sensor
power supply system
If failure code [CA2186] is indicated simultaneously, carry out trou-
bleshooting for it first.
2 Defective fuel control dial
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
P20 Voltage
Between (1) – (3) Power supply 4.75 – 5.25 V
Voltage is measured with wiring harness connected. Accordingly, if
voltage is abnormal, check wiring harness and controller, too, for
another cause of trouble, and then judge.
3
Ground fault in wiring har-
ness (Short circuit with GND
circuit)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J2 (female) (9) –
P20 (female) (2)
Resis-
tance
Min.
100 kz
4
Short circuit in wiring har-
ness (With another wiring
harness)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J2 (female) (9) –
P20 (female) (2) and between J2 (female)
(23) – P20 (female) (3)
Resis-
tance
Min.
100 kz
5
Defective wiring harness
connector
Connecting parts among fuel control dial, engine unit wiring har-
ness, and engine controller are suspected. Inspect them directly.
Loose connector, broken lock, broken seal
Corrosive, bent, broken, forced-in, or extended pin
Humidity in connector, entry of dirt or dust, poor insulation
6 Defective engine controller
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
J2 Voltage
Between (22) – (23) Power supply 4.75 – 5.25 V

Table of Contents