How to fix clogged supply air filter in Komfovent KOMPAKT REGO 1200 PE-EC Fan?
- BBrett SmithSep 12, 2025
If the supply air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
How to fix clogged supply air filter in Komfovent KOMPAKT REGO 1200 PE-EC Fan?
If the supply air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
How to fix clogged exhaust air filter in Komfovent Fan?
If the exhaust air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
What to do if supply air temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 1200 PE-EC?
If the supply air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if exhaust air temperature sensor is not connected or broken down in Komfovent Fan?
If the exhaust air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if outdoor temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 1200 PE-EC Fan?
If the outdoor temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if plate heat exchanger temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 1200 PE-EC Fan?
If the plate heat exchanger temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
How to reset electric heater overheating protection on Komfovent KOMPAKT REGO 1200 PE-EC Fan?
If the electric heater overheating protection is on in your Komfovent Fan, you can restore protection by pressing the “RESET” button located on the heater.
What to do if supply air temperature dropped lower allowable level in Komfovent Fan?
If the supply air temperature dropped lower than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
What to do if supply air temperature is higher allowable level in Komfovent Fan?
If the supply air temperature is higher than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
What to do if heater is disconnected due to low air flow in Komfovent Fan?
If the heater is disconnected due to low air flow in your Komfovent Fan, the protection restores automatically when the heater cools down. It is recommended to increase the ventilation intensity level.
Details required clearance for unit installation, service, and inspection.
Guidance on connecting modular sections of air handling units for proper assembly and sealing.
Instructions for properly connecting pipework to heating coils, ensuring support and load distribution.
Covers periodic checks for exchangers, fans, heaters, dampers, filters, and sensors for optimal performance.
Specific inspection procedures for air heaters, dampers, filter clogging, and pressure sensor settings.
Procedures for connecting unit sections and ensuring correct electric power supply and earthing.
Details on connecting external devices to the unit's connection boards.
Guidelines for correctly installing supply air and water temperature sensors in ducts and pipes.
Instructions for mounting the control panel in a suitable room environment and connecting it to the unit.
Explains unit control system components, panel operation, startup, and status indications.
How to view operating parameters and adjust ventilation levels and settings on the control panel.
Configuration options for unit operation modes, air volume control, temperature maintenance, and scheduling.
Covers remote control, ventilation correction, pump control, cooling recovery, and PC control features.